Handheld Patient Monitor

  • Product Detials:
    ModelSW1000

    Handheld Patient Monitor

    Features

    Five Parameters: ECG, NIBP, Pulse Rate, TEMP, SPO2.
     
    Waveforms:
    Two Waveforms: ECG waveform, SPO2 waveform (PLETH).
     
    Features:
    1.     Handheld; Compact, light, easy for carrying and handling.
    2.     Clear and bright LCD small screen real time display, Touch Screen.
    3.     Can be display the data and the waveform in a screen, and also can be switch between ECG waveform and PLETH.
    4.     English interface to simple read and handling.
    5.     Build-in rechargeable Ni/MH battery, longtime operating time.
    6.     Storage and review of patients trend data up to 36 hours which is never lost even when powers off.
    7.     Audio and visual alarm.
    8.      Battery capacity indicator.
    9.     Automatic power-off.
     
    Applications:
    Handheld patient monitor can be applied in the hospitals operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.
     
    Standard Packing List:
    1.  Handheld patient monitor main unit 1pc
    2.  3-lead ECG cable ( include surface TEMP probe) 1pc
    3.  Adult finger SpO2 sensor 1pc
    4.     Adult NIBP cuff 1pc
    5.     Child NIBP cuff 1pc
    6.     NIBP extension tube 1pc
    7.     AC power adaptor 1pc
    8.     electrode 6pcs
    9.     The operators manual 1pc
     
    Selectable Accessory:
    Child finger/toe SpO2 sensor
     
    Specifications:
    1. General Specifications:
    Size:150mmX114mmX45mm
    Weight:      600g
     
    Display Specification
    Measurement Display: 320x240 dot matrix homochromy LCD/touch screen
    Power Supply Indicator: Dual-color LED (red/green)
    Beat indicator: Red color LED
     
    AC Power Adaptor
    Input: 100-240VAC, 50/60Hz, 0.7A
    Output: DC 8V, 800mA
     
    Battery
    Ni/MH rechargeable 2AHr 6V battery 
    Operating Time: 6 hours with full battery capacity.
    ( Condition: 25oC, NIBP working period is 10 minutes. )
    Recharge Time: 10 hours.
     
    3.
    Temperature
    Working:0-45 (°C)
    Transport and Storage: -25- 85 (°C)
     
    Humidity
    Working:30% -85 %
    Transport and Storage: 30% -95 % (no condensation
     
    4. Monitoring Parameter
    ECG
    Input:3- lead ECG cable, standard AAMI cable connector
    Lead Selection:I,II,III
    Gain Selection:×1,×2,×4,×8
    Sweep Speed: 12.5, 25, and 50 mm/s
    Frequency Response: None filter: 0.05-100Hz (-3dB), filter: 0.5-40Hz (-3dB)
    Calibration Signal: 1mV square wave
    Protection: Against electrosurgical interference and defibrillation
     
    Heart Rate
    Measuring Range: 20-250 bpm
    Renew Time: 1 time per beat
    Accuracy: ±1 bpm
    Alarm Mode: Audible and visual alarm
     
    SpO2%
    Measuring Range: 35-99%
    Resolution:      1 %
    Accuracy:±2 %(70%-99%), unspecified (0%-69%)
    Pulse Rate
    Measuring and Alarm Range: 0-250bpm
    Resolution:      1bpm
    Accuracy: ±1bpm
     
    NIBP
    Method: Oscillometric
    Mode: Manual, Auto, STAT
    Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)
    Measuring Period in STAT Mode: 5 min
    Cuff Pressure Range: 0-300 (mmHg)
    Pulse Rate Range: 30-250 (bpm)
    Measurement Rage: Adult 30-255mmHg, Pediatric 30-160mmHg
    Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
    Pressure Resolution    : 1mmHg
    The SYSTOLIC and DIASTOLIC #118alues measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN #118alue measured using this device is equal to that measured using end artery blood pressure measurement device.
     
    Temperature
    Input: Body surface thermal-sensitive resistor temperature sensor
    Measuring Range: 0-50
    Accuracy: ±0.1
     
    Storage Method: Store measuring results once per minute
    Maximum Data Quantity: 2160 group
    Maximum Trend Time: Continuous 36 hours
Inquiry About Handheld Patient Monitor* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Ruian Yitai(Sunnyworld)Arts & Crafts(Medical Instruments)Co.,Ltd
Area: China/Zhejiang
Contact: Mr. Manny Chen
Tel: 86-577-65917211
Fax: 86-577-65910855
Web site: www.sunnyworld.cn
Add: 11 Building, Xingda Road, Ruian City, Zhejiang Province. China
Zip: 325200

Supplier's information
   Ruian Yitai(Sunnyworld)Arts & Crafts(Medical Instruments)Co.,Ltd

     Ruian Yitai (Sunnyworld) Arts & Crafts (Medical Instruments) Co., Ltd. with abundant manufactur ..... more >>

Contact: Mr. Manny Chen 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More