Patient Monitor 7 Channel

Patient Monitor 7 Channel
  • Product Detials:
    Patient Monitor 7 Channel
    Fuction & Specification
    Operating: Temperature 5~40 Humidity ≤80%
    Storage: Temperature -20~55  Humidity ≤93%
    Trend Observation :1~240 hours trend graphics
    Network: Compatible with central monitoring system
    Standard Configuration: ECG+RESP+NIBP+SpO2+HR(PR)+TEMP
    Optional: Built-in thermal printer,dual TEMP
    ECG
    Displaying graphics of 7 leads on the same screen
    Overload protection: Defibrillation.
    Anti the interference of high-frequency electrotome
    Lead: 5 Leads( RA,LA,RL,LL,V)
    Lead Selection: I; II;III; avR;avL;avF;V;
    Waveform:≤9 channels
    Gain Selection: X 0.5; X 1; X 2; X 4
    Electrical Leakage: <30uA
    Baseline Recovery Time: <3 sec following defibrillation
    Protection: separates and withstands 4000V AC/50Hz defibrillation, resistent to
    interference of electrotonus and myoelectricity
    Scan Speed: 12.5mm/25mm/50mm/sec
    Lead Drop:auto detection
    Modes: DIA 0.05~75Hz  MON:0.5~35Hz; OPE:1~25Hz
    RESP
    Model:RA-LL impedance
    Measurement/alarm range: 1~99rpm
    Resolution:1rpm.
    Accuracy:±2rpm
    TEMP
    Resolution: 0.1
    Accuracy:±0.2
    Channel: 2 channels
    Average measurement time: <10sec
    Alarm: Sound,light
    NIBP
    Method: automatic oscillometric
    Working Mode: Auto/Manual
    Interval of Auto Mode: 1~60min
    PR Range:0~300bpm
    Measurement Unit: mmHg/Kpa Selectable
    Measurement Ranges: Systolic BP, Diastolic BP and Mean BP
    Applicability: Adult/Pediatric/Neonatal
    Overload protection: Dual security protection
    SpO2
    SpO2 probe of high intensity and durability
    Excellent measurement of low perfusion
    Anti interference of movment
    Measurement Range:0~100%
    Alarm Range: 0~100%
    Resolution: ±1%
    Accuracy: ±2% (80-100%); ±3% (60-79%)
    PR Range:0~300bpm
    HR
    A. Measurment Range: 0~300bpm
    B. Accuracy: ±1 bpm or ±2%
    C. Resolution: 1bpm
    D. ECG Calibration:1 mV (Peak Value)
    ST Segment offset( Diagnose Mode)
    A. Measurment Range:-1.0mV ~ 1.0mV
    B. Accuracy:±0.02mV or ±5%
Inquiry About Patient Monitor 7 Channel* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Amax International Co.,Ltd
Area: China/Shandong
Contact: Mr. Robin Ge
Tel: +86-086-532-88735900,85781559,85710533
Fax: +86-086-532-88735955,85781560
Web site: www.cnamax.cn
Add: No.18 HongKong Middle Road, Qingdao, Shandong,China.
Zip: 266071

Supplier's information
   Amax International Co.,Ltd

     Amax International Co., Ltd. is professionally specialized in the line of medical equipment, an ..... more >>

Contact: Mr. Robin Ge 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More