Gas-Chromatograph

  • Product Detials:

    1)Brand-new designed microcomputer temperature control system of world advanced control technology. High accuracy of temperature control (optimum: ± 0.05°C), high reliability and anti-interference.

    2)Control and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time.

    3) Four paths of independent control sections: column oven, sample injector, detector and thermal conductive pond.

    4)5-ramp programmed temperature rising control. Auto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling.

    5) Dual FID provided with options of GC112 A-TCD, GC112A-ECD, GC 112 A-FPD and GC112A-NPD, gas sampling valve, transformation oven, absorber and pyrolysis absorber available for selection. Two detectors can be installed at the same time with high sensitivity. Short time to be stabilized and easy to clean and install nozzle.

    6) Packed column and capillary column (0.53 large diameter or small diameter) can be installed easily including a complete set of split sampling connector and tailing connector to be installed free of charge. Optional 0.53mm large diameter capillary direct sampler is available for choice.

    7)Analysis can be conducted in packed or capillary column with multiple sampling methods.

    Packed column: on-column sampling, instantaneous vaporized sampling and gas sampling.

    Capillary column: split sampling and 0.53mm large diameter capillary direct sampling. ? Construction of dual gas path, dual sample injector and dual packed column system can effectively avoid baseline undulation and drift in real time and facilitate programmed temperature rising analysis. Accurate and scaled type gas path control valves will provide a high repeatability and stability.

    8) Advanced functions: auto ON/OFF temperature control system, permanent data storage, file storage and call and over-temperature protection.

    9) Large volume column (300x280x270) can hold capillary column and dual packed column. Built-in heating filament structure is in favor of quartz capillary analysis.

    Specifications

    Temperature control

    Control range

    7°C - 400°C above room temperature. (increment of 1°C)

    Control objects

    column oven, detector, thermal conductive pond and sample injector

    Programmed temperature rising

    5 ramps

    Rate of programmed temperature rising

    0.1°C -40°C

    (increment of 0.1°C)

    Thermostatic time

    0-655 min

    (increment of 1 min)

    FID

    Sensitivity (minimum testability)

    M£5´10-11 g/s (sample: C16)

    Optimum testing result

    M£1´10-11 g/s

    Noise

    £5´10-14 A

    Drift

    £6´10-13 A/h

    Linear range

    ³106

    TCD

    Sensitivity

    ³2000mV.ml/mg

    Noise

    £20mV

    Drift

    £30mV

    Linear range

    ³104

    ECD

    Temperature range

    350°C Max

    Measuring mode

    63Ni

    Sensitivity

    £10-13 g (Benzex)

    Linear range

    ³103

     FPD

    Sensitivity (minimum testability)

    £2´10-11 g (P)/s (sample P in the parathion methyl)

    Optimum testing result: £3.8´10-12 g (P)/s.

    Sensitivity (minimum testability)

    £1´10-10 g (S)/s (sample: S in the parathion methyl)

    Optimum testing result: £2.7´10-11 g (S)/s

    Linear range

    ³103 (sample P parathion)

    ³102 (sample S parathion)

    Stability

    £30mV/h

    Noise

    £10mV

    Starting time

    not greater than 2 hours

     NPD:

    Sensitivity (minimum testability)

    Dt(N)£5pg (N)/s (sample: azobenzene)

    Optimum testing result: 0.5ppm

    Sensitivity (minimum testability)

    Dt(P) £0.5pg (P)/s (sample: malethion)

    Optimum testing result: 0.2ppm

    Drift

    £8´10-13 A/h

    Noise

    £5´10-13 A

    Linear range

    ³103

    Max application temperature

    360°C

Inquiry About Gas-Chromatograph* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Shanghai Zdan International Co.,Ltd
Area: China/Shanghai
Contact: Ms. Snow Zhang
Tel: +86-086-021-54746006
Fax: +86-086-021-54746005
Web site:
Add: Room 1103, No.7, Lane 99, Jinggu East Road,Shanghai City(200240), China.