Translate :  China

Popular Searches : Surgical face mask , Dental Chair , wheelchair , Stethoscope , feeding tube , Instrument Trolley , Infusion Set , vacuum blood collect more>>
Home > Products > Blood pressure monitor , you home doctor!
 KR

Blood pressure monitor , you home doctor!

  • Scope:Wrist
  • Product Detials:

    Basic information:

     

     Name:
          Blood Pressure Monitor 
     

    Product Features :
    * Intelligent automatic compression and decompression
    * At the same time, systolic blood pressure measurements, blood pressure and pulse
    * Easy, simply by switching button can be tested
    * 60 store group memory measurements
    * Can be found in a single or all of the measurements
    * 3 minutes automatic power saving device
    * Intelligent device debugging, automatic power to detect
    * Local tests for: wrist circumference to 135 ~ 195mm
    * The number of large-scale LCD screen
    * High-accuracy
     
    Usage way:
    Install or replace the battery

    1, the battery is installed:

    According to the battery cover the direction of the arrow to open the battery cover, according to an internal battery (+),(-) marked symbols into 2 AAA alkaline batteries, and then slide the battery cover close.

    2, to replace the battery:

    The machine will automatically detect the power to display symbols appear when the power shortage, said the lack of electricity, re-confirmed that the battery polarity, or the immediate replacement of 2 new AAA alkaline batteries, or will not be able to feel the pulse and blood pressure measurements, and with sphygmomanometer Storage of measurements and time settings will be lost.

    With the use of the wrist

    1, palms up, blood pressure monitors are also facing upward, and with the wrist wrapped in from the left wrist joints 5 ~ 10mm Office (about one finger width).

    2, to seize the wrist band at the end of the following, and pulling in the same time, their wrists tied to the volume, stick to up Guoshang strain, wrist strap and not to leave gaps between.

    3, wrist band too long, can be properly fixed anti-fold.

    Measuring the correct posture

    Sitting to be measured, can be left on the table, or in accordance with the actual demand increases blood pressure pad incorporated or pillow case, the pressure to adjust the location of the wrist band. The pad can add items to bring down the wrist, so as not to affect the measurement values.

    How to measure blood pressure

    In order to understand your blood pressure, blood pressure measuring a fixed time every day. Please refer to the measurements before the "pre-measured", "wrist band to use", "Measuring the correct posture," and so on.

    1, with wrists tied to the wrist, palms up will be relaxed so that the wrists with the location of the heart and with the high.

    2, according to the power supply to open the key to open. The screen shows all the signs will be like when the screen flashes numbers 0 to stop, to start measuring.

    3, and then click open the key to start measuring, and wrist band into the air around 180mmHg blood pressure in the inflatable screen will appear when the inflatable symbol (measured in Yaoshou or do not speak).

    4, after the completion of the pressure, the pressure will gradually decline, measured after the pulse, heart-shaped symbol will begin flashing simultaneously with the heartbeat. (Note: If possible high blood pressure, blood pressure may be discouraged to stop, and will automatically pump pressure to the ideal pressure).

    To read the measurement value

    1, automatic storage of measurements

    Every time measurement is completed, the machine automatically stored measurements of systolic blood pressure, pulse and blood pressure, can store up to the old measurements will be automatically deleted and replaced by the latest measurements.

    2, to read a single measurement:

    Under normal conditions, according to the memory keys to read the latest measurements (systolic pressure, diastolic blood pressure and pulse a few), then click the button memory can be read in the next set of data, according to repeat the key memory storage in order to read the information. (M01, said the latest measurements, M02, said last second measurements, and so on).
     
    Notes :
    1, will do blood pressure after the closure of the battery and then replace the battery. If first blood pressure monitor and direct the closure of the power to replace the battery, or no more than 30 seconds when the battery is installed, the machines stored in all the measurements will be lost.

    2, please wrists bound volume with bare wrists, not the clothes volume in the sleeve onto the wrist.

    3, do not pull too hard with your wrist so that the volume up too tight, if they can not be in the right wrist with Banghao, will not be able to correct the blood pressure measured. If there is an independent operator, should seek the help of others so as to the proper use.

    4, in order to do the right measured blood pressure, make sure the wrist band and the location of the heart to maintain the same high level, palms upward force can not relax, to finish at five to six deep breath after the measure can be measured in the right values. With wrist position and the heart must maintain the same level of high, too low or too high will have a measurement error. If the wrist band is too low or too tightly tied, the measurement of blood pressure may be on the high side.

    5, wrist strap if it has been in a state of inflation can not be stopped, immediately remove wrist belt, or a key to open the machine will be shut down. Do not for the time being because of the high-value or low value and tension, a day at fixed times to measure and record blood pressure, doctors and professional advice.
Inquiry About Blood pressure monitor , you home doctor!* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Guangzhou Huakang Electronic Technology Co.,Ltd
Area: China/Guangdong
Contact: Mr. Eric(Trade Deparment)
Tel: 86-13533788524
Fax: 86-20-81507743
Web site: www.hkzly.com
Add: 3rd Floor, Building A, No. 17 Hejing South Road, Dongsha Industrial Park, Fangcun Liwan District, Guangzhou, Guangdong, China
Zip: 510358

Supplier's information
   Guangzhou Huakang Electronic Technology Co.,Ltd

     Guangzhou Huakang Electronic Technology Co., Ltd., established in 1993 is specialized in resear ..... more >>

Contact: Mr. Eric(Trade Deparment) 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More