Translate :  China

Popular Searches : medical equipment , syringe , Wound Plaster , Tourniquet , Pulse Oximeter , disposable syringe , fetal monitor , Ultrasound Scanner more>>
Home > Products > Handheld ECG, ECG Machine, ECG Monitor Electrocardiograph (LDM-100)
 KR

Handheld ECG, ECG Machine, ECG Monitor Electrocardiograph (LDM-100)

Handheld ECG, ECG Machine, ECG Monitor Electrocardiograph (LDM-100)
  • Product Detials:ECG-LDM100 Digital 1 Channel & Wave LCD Technical Parameters 1...Hand held ECG 19*9*3, 5 CM 2...High resolution thermal printing array system 3...High frequency response reach to 150Hz 4...Rhythm Lead selectable 5...LCD impuls wave 6...Capable of printing continuous one channel trace and annotations including lead mark And such parameters as sensitivity, paper speed, and filter The Heart The heart is an organ responsible for pumping the blood in the body. Through the blood, nutrients are provided to the body's cells and waste products are removed from these cells. The heart has four chambers: Two upper chambers which are called atria and two lower chambers which are called ventricles. These chambers are also classified as left and right atrium and left and right ventricle, and each of them has a specific function. A schematic frontal section through the human's heart is presented in the following figure. The heart pumps the blood by repeated contractions of its muscles. These cardiac contractions are produced due to an electrical phenomenon called depolarization, that takes place in the heart muscles' cells (myocardial cells). The myocardial cells have a negative electric resting potential. Through the depolarization, this potential goes temporarily to a positive value that stimulates them to contract. Each heart cycle consists of two phases: Depolarization, which represents the myocardial stimulation and repolarization, which represents the recovery phase. Both depolarization and repolarization are electrical phenomena. Specialized conductive fibers inside the myocardium allow the transmission of cardiac stimulus to all the myocardial cells in a specific order. The atria contract first, and then the ventricles. Under normal conditions, the cardiac stimulus originates in a point, called sinoatrial node or sinus node, located in the posterior wall of the right atrium. The property of the node's cells to fire automatically and periodically an electric stimulus is called automaticity. However, the automaticity is a property posessed by all myocardial cells. In case the sinoatrial node fails to fire a stimulus, other myocardial cells will initiate this stimulation automatically. The stimulus generated by the sinoatrial node is propagated as a wave of depolarization and stimulates both atria. The depolarization wave produces a current wave of atrial contraction, which is called the P wave, as presented in the following figure. After a puse of about 1/10 of a second, the atrial depolarization wave reaches the atrioventricular node, which is situated between the two sets of chambers. The electrical stimulus passes then from the atrioventricular node through the bundle of His to the atrioventricular bundle branches, and the Purkinje fibers, which initiate the ventricular depolarization. The ventricular depolarization is represented graphically on the electrocardiogram by an abrupt waveform called QRS complex, as presented in the following figure. During the ventricular depolarization, the right and Left ventricles contracts and pump the blood they contain. The QRS complex consists of three distinctive waves: Q, R and S. After the QRS complex, there is a pause, called ST segment. During the ventricular repolarization, which is represented by the T wave, the heart cells regain the negative polarization. The sinoatrial node stimulates the heart at a rate of 60-80 beats per minute. If the senatorial node fails to fire an impulse, other cells from atria can do that instead. If this does not happen, then the artioventricular node can fire impulses at a rate of about 40-60 times per minute. Further, if no excitation occurs from the previous sources, the ventricular cells can fire a depolarization at a rate of about 20-40 times per minute.
Inquiry About Handheld ECG, ECG Machine, ECG Monitor Electrocardiograph (LDM-100)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Qingdao Devonmed Medical Equipment Co.,Ltd
Area: China/Shandong
Contact: Mr. Ethan
Tel: 86-532-88750192
Fax: 86-532-88750192
Web site:
Add: No. 63 Western Hong Kong Road Qingdao
Zip: 266071

Supplier's information
   Qingdao Devonmed Medical Equipment Co.,Ltd

     DevonMediTech is a special global provider of medical devices for the hospital, emergency, home ..... more >>

Contact: Mr. Ethan 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More