Translate :  China

Popular Searches : medical equipment , syringe , Wound Plaster , Tourniquet , Pulse Oximeter , disposable syringe , fetal monitor , Ultrasound Scanner more>>
Home > Products > Multiparameter Patient Monitor 8.4 (NT3E)
 KR

Multiparameter Patient Monitor 8.4 (NT3E)

Multiparameter Patient Monitor 8.4 (NT3E)
  • Product Detials:8.4" High Brightness TFT LCD 1-8 Channel Waveform Display 7 Channel ECG Waveform Display; ST Segment Analysis; Anti-movement and low perfusion SpO2 Measurement Pace Pulse Detection Defibrillation and ESU Protection OxyCRG diagram; Drug Dose Calculation Venous Punch Flexible Parameter Configuration Multiparameter Patient Monitor (8.4 " Display) Product Features: ECG ECG Cable: 5 Leadwires ECG cable Lead section: Lead I, II, III/aVR, aVL, aVF/ V Gain(mm/mV): 1/4, 1/2, 1, 2, 4 Frequency response: Diagnosis: 0.05 - 100Hz Monitor: 0.5~40 Hz Surgery: 1.0~25 Hz Sweep speed(mm/sec): 6.25, 12.5, 25, 50 Heart rate range: 0-350 BPM Heart rate accuracy: ± 1 % ST segment deviation analysis: -0.8~+0.8mV ST accuracy: ± 0.02mv Non-Invasive Blood Pressure Measurement type: Adult, pediatric, neonatal Measurement range: Systolic 4.0 - 270mmHg Diastolic 20 - 200mmHg Mean 30 - 220mmHg Accuracy: ± 3mmHg or 2 %(choice max) Resolution: 1mmHg Protection: Over pressure Pules Oximetry SPO2 measurement range: 0 - 100 % Accuracy: ± 2% at 70~100% (no specification under 70%) Resolution: 1 % Pulse measurement range: 30- 250BPM Accuracy: ± 2 % or 1BPM (choice max) Resolution: 1 BPM Respiration Rate Measurement range: 0 - 120 BPM Accuracy: ± 1 BPM or 5 %(choice max) Resolution: 1 BPM CO2 Measurement range: 0 % - 10.0 % (in CO2 and et CO2) Accuracy: ± 2 mm Hg(<5 % Measurement value) ± 10 % (>5 % Measurement value) Response time: 180 ms IBP Channel number: 2ch Range: -40 - +330mmHg Accuracy: ± 4mmHg or ± 4%(choice max) Resolution: 1mmHg Environment Opreation Storage Temperature: 5~40 º C -20~70 º C Relative humidity: ≤ 80% ≤ 95% Temperature Channel number: 2ch Measurement range: 25~45 º C Accuracy: ± 0.1 º C Resolution: 0.1 º C Response time: ≤ 3 min Power Requirements Input: 98-260 V AC, 50/60Hz Consumption: ≤ 80VA More Product Features Trademark: Newtech Model NO.: NT3E Standard: CE,ISO13485:2003 Origin: Shenzhen Guangdong,China Company: Newtech, Inc.
Inquiry About Multiparameter Patient Monitor 8.4 (NT3E)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Newtech,Inc
Area: China/Guangdong
Contact: Ms. Shirely Wang(Internati
Tel: 86-755-26546717
Fax: 86-755-26546719
Web site: http://www.sznewtech.com
Add: R1-B1, South Area, Hi-Tech Industry Park, Nanshan District, Shenzhen, Guangdong, China
Zip: 518057

Supplier's information
   Newtech,Inc

     Newtech, Inc., a privately owned company founded in 1998, is one of the fastest growing medical ..... more >>

Contact: Ms. Shirely Wang(Internati 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More