Translate :  China

Popular Searches : Surgical face mask , Dental Chair , wheelchair , Stethoscope , feeding tube , Instrument Trolley , Infusion Set , vacuum blood collect more>>
Home > Products > Patient Monitor (PM810)
 KR

Patient Monitor (PM810)

Patient Monitor (PM810)
  • Product Detials:Character Host computer frame: Advanced streamline outline design Displayer: 10.4"color TFT LCD screen HR. TEMP. SPO2. NIBP 12, 24, 96, 720 hours trend analysis NIBP. HR. SPO2. TEMP. RESP list 2880 Can use with protection against interference from defibrillator and ESU(electric surgical unit), pacemaker detection Function on network with central monitoring system Chinese / English operating menu interface: Modularize design Electrocardiograph (ECG) Heart rate ranges: Adult. 20—250. Bpm Ranges: Pediatric /Neonatal 5—250bpm Bandwidth: 0.05-100HZ Accuracy: +-1% Lead selection: GND. I, II, III, avR, avL, avF, V1-V6 Resolution: 1bpm ST Segment. Monitor: -2.0-2.0mv Scan speed: 12.5mm/s. 25mm/s. 50mm/s VPC. Analysis VPC. Record. 50times HRV analysis (selective) ST Segment. Analysis. Five minutes. ECG record graph HR Lead wires: Adult. Neonatal. Pediatric Gain: Auto. X1/2, X1, X2 Non-Invasive blood pressure Measurement. Method: Intelligent oscillometric Measurement parameter: Systolic. Diastolic. Mean and sphygmic Working mode: Auto/ manual. Measure series Five minutes Measurement unit: MmHg/ Kpa. Selectable Measurement range: 0—250mmHg Cuff. Pressure: 0—320mmHg Incidental cuff: Adult SPO2 Measurement range: 0—100% Resolution: 1% Accuracy: +- 1%(70—100%), +- 2%(50—69%) PR ranges: 0-255bpm PR Accuracy: +- 2bpm Incidental sensor: Adult finger TEMP: Measurement ranges: 20--45degree Unit: Celsius/ Fahrenheit. Selectable Resolution: 0.1degree Accuracy: +-0.1degree Incidental sensor: Surface Temp RESP: Measurement method: Impedance Measurement ranges: 0—120times/min Accuracy: +-2bpm CO2: Measurement method: Selective Measurement parameter: HR. Ec/Ti CO2 Measurement accuracy: +-2mmHg Measurement ranges: 0—99mmHg Barometric ranges: 500—800mmHg IBP: (single ---Dual Selectable) Measurement method: Pressure sensor Measurement parameter: Systolic BP. Diastolic BP. Mean BP Measurement accuracy: +-2% Measurement part: Artery, pulmonary artery. Encephalic. Center artery, right heart, left heart Measurement range: Artery 0—250mmHg Pulmonary artery: 0—120mmHg Vena: -10—40mmHg Optional: Printer: Internal or external Cuff: Pediatric /Neonatal Pulse sensor: Y. Type. Sensor, Pediatric Sensor Temp sensor: Rectal inductor / nonnasality inductor Collocation Standard configuration: HR NIBP SPO2 RESP TEMP PR built-in battery Optional: Internal /external printer Single—Dual. NIBP CO2 Trademark: KANGPU Model NO.: PM810 Company: Kangpu Medical Supply Co., Ltd.
Inquiry About Patient Monitor (PM810)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Kangpu Medical Supply Co.,Ltd
Area: China/Guangdong
Contact: Ms. Nancy(Export Departmen
Tel: 86-20-32784767
Fax: 86-20-36826608
Web site:
Add: Bangyi Factory City, Guangzhou, Guangdong, China
Zip: 510663

Supplier's information
   Kangpu Medical Supply Co.,Ltd

     We have our own factory, designing and producing the medical products by ourselves. Maybe now w ..... more >>

Contact: Ms. Nancy(Export Departmen 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More