Translate :  China

Popular Searches : medical equipment , syringe , Wound Plaster , Tourniquet , Pulse Oximeter , disposable syringe , fetal monitor , Ultrasound Scanner more>>
Home > Products > Patient Monitor (MT-8000S)
 KR

Patient Monitor (MT-8000S)

Patient Monitor  (MT-8000S)
  • Product Detials:Specification
    12.1 inch TFT; Resolution: 800*600
    ECG, SpO2, PR, NIBP, RR, Tem.

    Specifications
    Operating condition
    Working Storage
    Temperature: 0-40 -20-70
    Humidity: 15-95% 10- 90%

    Power supply
    External power requirement: AC 100-250V 50/60Hz

    Classification
    Anti-electroshock type Class I equipment
    Anti-electroshock degree CF defibrillation;

    Accordant Standard
    GB9706.1: 1995
    GB/T14710: 1993
    YY0089: 1992
    YY91079: 1999

    ECG
    Leads Mode: 5 leads: I\II\III\Avr\Avl\Avf\V
    Gain(mm/mV): 1/4, 1/2, 1, 2, 4
    Scanning speed; 12.5mm/s\25mm/s\50mm/s
    Frequency response: Diagnosis 0.05-130Hz
    Monitoring 0.5-40Hz
    Operation 1.0- 20Hz
    Heart rate range: 15-350 BPM
    Heart rate accuracy: ± 1%
    ST segment analysis: -0.8-+0.8Mv
    ST segment accuracy: ± 0.02Mv

    NIBP
    Measure and Alarm Range
    Adult Mode
    SYS 40 ~ 280 mmHg
    DIA 10 ~ 220 mmHg
    MEAN 20 ~ 240 mmHg
    Pediatric Mode
    SYS 40 ~ 220 mmHg
    DIA 10 ~ 160 mmHg
    MEAN 20 ~ 170 mmHg
    Neonatal Mode
    SYS 40 ~ 135 mmHg
    DIA 10 ~ 100 mmHg
    MEAN 20 ~ 110 mmHg

    Static pressure range: 0~300 mmHg
    Static pressure accuracy: ± 3 mmHg or 2%
    Resolution: 1mmHg
    Protection mode: Dual over voltage protection.

    SpO2
    Measure range: 1-100%
    Accuracy: ± 2% (70-100%)
    Resolution: 1%

    Pulse rate
    Measure range: 20-300 BPM
    Accuracy: ± 2BPM
    Resolution: 1BPM

    Temperature
    Channel: 2
    Measure range: 0-50
    Accuracy: ± 0.1
    Resolution: 0.1

    Respiration
    Measure range: Adult 0~120BrPM
    Pediatric/ Neonatal 0~150BrPM
    Accuracy: ± 2%
    Resolution: 1BPM

    IBP(optional)
    Accuracy (no sensor): ± 2% or1mmHg
    Band width: Normal mode: DC~40Hz
    Smooth mode: DC~12.5Hz

    ETCO2
    Measure range: 0% - 13%
    Resolution: 1 mmHg
    Accuracy: ± 2 mmHg @ < 5.0% CO2 (at ATPS)
    Respiration: 3 -150 BPM

    Function
    * 6 display interface
    * 720 hours trend data storage, 12 hours waveform review
    * voice alarm
    * support wired and wireless networking
    * support software upgrade online.

    Option
    Lead-acid battery (built-in)
    Recorder (built-in)
    IBP
    ETCO2.
Inquiry About Patient Monitor (MT-8000S)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Shenzhen Mature Medical Equipment Co.,Ltd
Area: China/Guangdong
Contact: Ms. Jessie(Sales Department)
Tel: 86-755-27960309
Fax: 86-755-27960306
Web site: http://www.szmature.com
Add: Building No. 1, The First Sub-Park Of Taohuayuan Technology & Innovation Park Baoan, Shenzhen, Guangdong, China
Zip:

Supplier's information
   Shenzhen Mature Medical Equipment Co.,Ltd

     We provide medical equipment including fetal doppler, fetal monitor, patient monitor ECG machin ..... more >>

Contact: Ms. Jessie(Sales Department) 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More